The RP40-FR series wide range input DC/DC converters have been especially designed for railway applications and are EN50155 certified. They are also certified to UL60950-1 and cUL 60950-1, this makes them ideal for all high input voltage telecom and industrial applications where approved safety standards are required.
| Part Number | Power (W) | Isolation | Vin (V) | Main Vout (V) | Package Style | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 |   | RP40-11005SFR/N | 40 | Isolated | 43 - 160 | 4.5 to 5.5 | 2"x1" |  | ||||||
| 2 |   | RP40-11005SFR/N-HC | 40 | Isolated | 43 - 160 | 4.5 to 5.5 | 2"x1" |  | ||||||
| 3 |   | RP40-11005SFR/P | 40 | Isolated | 43 - 160 | 4.5 to 5.5 | 2"x1" |  | ||||||
| 4 |   | RP40-11005SFR/P-HC | 40 | Isolated | 43 - 160 | 4.5 to 5.5 | 2"x1" |  | ||||||
| 5 |   | RP40-11012DFR/N | 40 | Isolated | 43 - 160 | ± 12 | 2"x1" |  | ||||||
| 6 |   | RP40-11012DFR/N-HC | 40 | Isolated | 43 - 160 | ± 12 | 2"x1" |  | ||||||
| 7 |   | RP40-11012DFR/P | 40 | Isolated | 43 - 160 | ± 12 | 2"x1" |  | ||||||
| 8 |   | RP40-11012DFR/P-HC | 40 | Isolated | 43 - 160 | ± 12 | 2"x1" |  | ||||||
| 9 |   | RP40-11012SFR/N | 40 | Isolated | 43 - 160 | 10.8 to 13.2 | 2"x1" |  | ||||||
| 10 |   | RP40-11012SFR/N-HC | 40 | Isolated | 43 - 160 | 10.8 to 13.2 | 2"x1" |  | ||||||
| 11 |   | RP40-11012SFR/P | 40 | Isolated | 43 - 160 | 10.8 to 13.2 | 2"x1" |  | ||||||
| 12 |   | RP40-11012SFR/P-HC | 40 | Isolated | 43 - 160 | 10.8 to 13.2 | 2"x1" |  | ||||||
| 13 |   | RP40-11015DFR/N | 40 | Isolated | 43 - 160 | ± 15 | 2"x1" |  | ||||||
| 14 |   | RP40-11015DFR/N-HC | 40 | Isolated | 43 - 160 | ± 15 | 2"x1" |  | ||||||
| 15 |   | RP40-11015DFR/P | 40 | Isolated | 43 - 160 | ± 15 | 2"x1" |  | ||||||
| 16 |   | RP40-11015DFR/P-HC | 40 | Isolated | 43 - 160 | ± 15 | 2"x1" |  | ||||||
| 17 |   | RP40-11015SFR/N | 40 | Isolated | 43 - 160 | 13.5 to 18 | 2"x1" |  | ||||||
| 18 |   | RP40-11015SFR/N-HC | 40 | Isolated | 43 - 160 | 13.5 to 18 | 2"x1" |  | ||||||
| 19 |   | RP40-11015SFR/P | 40 | Isolated | 43 - 160 | 13.5 to 18 | 2"x1" |  | ||||||
| 20 |   | RP40-11015SFR/P-HC | 40 | Isolated | 43 - 160 | 13.5 to 18 | 2"x1" |  | ||||||
| 21 |   | RP40-11024DFR/N | 40 | Isolated | 43 - 160 | ± 24 | 2"x1" |  | ||||||
| 22 |   | RP40-11024DFR/N-HC | 40 | Isolated | 43 - 160 | ± 24 | 2"x1" |  | ||||||
| 23 |   | RP40-11024DFR/P | 40 | Isolated | 43 - 160 | ± 24 | 2"x1" |  | ||||||
| 24 |   | RP40-11024DFR/P-HC | 40 | Isolated | 43 - 160 | ± 24 | 2"x1" |  | ||||||
| 25 |   | RP40-11024SFR/N | 40 | Isolated | 43 - 160 | 21.6 to 28.8 | 2"x1" |  | ||||||
| 26 |   | RP40-11024SFR/N-HC | 40 | Isolated | 43 - 160 | 21.6 to 28.8 | 2"x1" |  | ||||||
| 27 |   | RP40-11024SFR/P | 40 | Isolated | 43 - 160 | 21.6 to 28.8 | 2"x1" |  | ||||||
| 28 |   | RP40-11024SFR/P-HC | 40 | Isolated | 43 - 160 | 21.6 to 28.8 | 2"x1" |  | ||||||
| 29 |   | RP40-1103.3SFR/N | 40 | Isolated | 43 - 160 | 2.97 to 3.63 | 2"x1" |  | ||||||
| 30 |   | RP40-1103.3SFR/N-HC | 40 | Isolated | 43 - 160 | 2.97 to 3.63 | 2"x1" |  | ||||||
| 31 |   | RP40-1103.3SFR/P | 40 | Isolated | 43 - 160 | 2.97 to 3.63 | 2"x1" |  | ||||||
| 32 |   | RP40-1103.3SFR/P-HC | 40 | Isolated | 43 - 160 | 2.97 to 3.63 | 2"x1" |  | ||||||
| 33 |   | RP40-2405SFR/N | 40 | Isolated | 9 - 36 | 4.5 to 5.5 | 2"x1" |  | ||||||
| 34 |   | RP40-2405SFR/N-HC | 40 | Isolated | 9 - 36 | 4.5 to 5.5 | 2"x1" |  | ||||||
| 35 |   | RP40-2405SFR/P | 40 | Isolated | 9 - 36 | 4.5 to 5.5 | 2"x1" |  | ||||||
| 36 |   | RP40-2405SFR/P-HC | 40 | Isolated | 9 - 36 | 4.5 to 5.5 | 2"x1" |  | ||||||
| 37 |   | RP40-2412DFR/N | 40 | Isolated | 9 - 36 | ± 12 | 2"x1" |  | ||||||
| 38 |   | RP40-2412DFR/N-HC | 40 | Isolated | 9 - 36 | ± 12 | 2"x1" |  | ||||||
| 39 |   | RP40-2412DFR/P | 40 | Isolated | 9 - 36 | ± 12 | 2"x1" |  | ||||||
| 40 |   | RP40-2412DFR/P-HC | 40 | Isolated | 9 - 36 | ± 12 | 2"x1" |  | ||||||
| 41 |   | RP40-2412SFR/N | 40 | Isolated | 9 - 36 | 10.8 to 13.2 | 2"x1" |  | ||||||
| 42 |   | RP40-2412SFR/N-HC | 40 | Isolated | 9 - 36 | 10.8 to 13.2 | 2"x1" |  | ||||||
| 43 |   | RP40-2412SFR/P | 40 | Isolated | 9 - 36 | 10.8 to 13.2 | 2"x1" |  | ||||||
| 44 |   | RP40-2412SFR/P-HC | 40 | Isolated | 9 - 36 | 10.8 to 13.2 | 2"x1" |  | ||||||
| 45 |   | RP40-2415DFR/N | 40 | Isolated | 9 - 36 | ± 15 | 2"x1" |  | ||||||
| 46 |   | RP40-2415DFR/N-HC | 40 | Isolated | 9 - 36 | ± 15 | 2"x1" |  | ||||||
| 47 |   | RP40-2415DFR/P | 40 | Isolated | 9 - 36 | ± 15 | 2"x1" |  | ||||||
| 48 |   | RP40-2415DFR/P-HC | 40 | Isolated | 9 - 36 | ± 15 | 2"x1" |  | ||||||
| 49 |   | RP40-2415SFR/N | 40 | Isolated | 9 - 36 | 13.5 to 18 | 2"x1" |  | ||||||
| 50 |   | RP40-2415SFR/N-HC | 40 | Isolated | 9 - 36 | 13.5 to 18 | 2"x1" |  | ||||||
| 51 |   | RP40-2415SFR/P | 40 | Isolated | 9 - 36 | 13.5 to 18 | 2"x1" |  | ||||||
| 52 |   | RP40-2415SFR/P-HC | 40 | Isolated | 9 - 36 | 13.5 to 18 | 2"x1" |  | ||||||
| 53 |   | RP40-2424DFR/N | 40 | Isolated | 9 - 36 | ± 24 | 2"x1" |  | ||||||
| 54 |   | RP40-2424DFR/N-HC | 40 | Isolated | 9 - 36 | ± 24 | 2"x1" |  | ||||||
| 55 |   | RP40-2424DFR/P | 40 | Isolated | 9 - 36 | ± 24 | 2"x1" |  | ||||||
| 56 |   | RP40-2424DFR/P-HC | 40 | Isolated | 9 - 36 | ± 24 | 2"x1" |  | ||||||
| 57 |   | RP40-2424SFR/N | 40 | Isolated | 9 - 36 | 21.6 to 28.8 | 2"x1" |  | ||||||
| 58 |   | RP40-2424SFR/N-HC | 40 | Isolated | 9 - 36 | 21.6 to 28.8 | 2"x1" |  | ||||||
| 59 |   | RP40-2424SFR/P | 40 | Isolated | 9 - 36 | 21.6 to 28.8 | 2"x1" |  | ||||||
| 60 |   | RP40-2424SFR/P-HC | 40 | Isolated | 9 - 36 | 21.6 to 28.8 | 2"x1" |  | ||||||
| 61 |   | RP40-243.3SFR/N | 40 | Isolated | 9 - 36 | 2.97 to 3.63 | 2"x1" |  | ||||||
| 62 |   | RP40-243.3SFR/N-HC | 40 | Isolated | 9 - 36 | 2.97 to 3.63 | 2"x1" |  | ||||||
| 63 |   | RP40-243.3SFR/P | 40 | Isolated | 9 - 36 | 2.97 to 3.63 | 2"x1" |  | ||||||
| 64 |   | RP40-243.3SFR/P-HC | 40 | Isolated | 9 - 36 | 2.97 to 3.63 | 2"x1" |  | ||||||
| 65 |   | RP40-4805SFR/N | 40 | Isolated | 18 - 75 | 4.5 to 5.5 | 2"x1" |  | ||||||
| 66 |   | RP40-4805SFR/N-HC | 40 | Isolated | 18 - 75 | 4.5 to 5.5 | 2"x1" |  | ||||||
| 67 |   | RP40-4805SFR/P | 40 | Isolated | 18 - 75 | 4.5 to 5.5 | 2"x1" |  | ||||||
| 68 |   | RP40-4805SFR/P-HC | 40 | Isolated | 18 - 75 | 4.5 to 5.5 | 2"x1" |  | ||||||
| 69 |   | RP40-4812DFR/N | 40 | Isolated | 18 - 75 | ± 12 | 2"x1" |  | ||||||
| 70 |   | RP40-4812DFR/N-HC | 40 | Isolated | 18 - 75 | ± 12 | 2"x1" |  | ||||||
| 71 |   | RP40-4812DFR/P | 40 | Isolated | 18 - 75 | ± 12 | 2"x1" |  | ||||||
| 72 |   | RP40-4812DFR/P-HC | 40 | Isolated | 18 - 75 | ± 12 | 2"x1" |  | ||||||
| 73 |   | RP40-4812SFR/N | 40 | Isolated | 18 - 75 | 10.8 to 13.2 | 2"x1" |  | ||||||
| 74 |   | RP40-4812SFR/N-HC | 40 | Isolated | 18 - 75 | 10.8 to 13.2 | 2"x1" |  | ||||||
| 75 |   | RP40-4812SFR/P | 40 | Isolated | 18 - 75 | 10.8 to 13.2 | 2"x1" |  | ||||||
| 76 |   | RP40-4812SFR/P-HC | 40 | Isolated | 18 - 75 | 10.8 to 13.2 | 2"x1" |  | ||||||
| 77 |   | RP40-4815DFR/N | 40 | Isolated | 18 - 75 | ± 15 | 2"x1" |  | ||||||
| 78 |   | RP40-4815DFR/N-HC | 40 | Isolated | 18 - 75 | ± 15 | 2"x1" |  | ||||||
| 79 |   | RP40-4815DFR/P | 40 | Isolated | 18 - 75 | ± 15 | 2"x1" |  | ||||||
| 80 |   | RP40-4815DFR/P-HC | 40 | Isolated | 18 - 75 | ± 15 | 2"x1" |  | ||||||
| 81 |   | RP40-4815SFR/N | 40 | Isolated | 18 - 75 | 13.5 to 18 | 2"x1" |  | ||||||
| 82 |   | RP40-4815SFR/N-HC | 40 | Isolated | 18 - 75 | 13.5 to 18 | 2"x1" |  | ||||||
| 83 |   | RP40-4815SFR/P | 40 | Isolated | 18 - 75 | 13.5 to 18 | 2"x1" |  | ||||||
| 84 |   | RP40-4815SFR/P-HC | 40 | Isolated | 18 - 75 | 13.5 to 18 | 2"x1" |  | ||||||
| 85 |   | RP40-4824DFR/N | 40 | Isolated | 18 - 75 | ± 24 | 2"x1" |  | ||||||
| 86 |   | RP40-4824DFR/N-HC | 40 | Isolated | 18 - 75 | ± 24 | 2"x1" |  | ||||||
| 87 |   | RP40-4824DFR/P | 40 | Isolated | 18 - 75 | ± 24 | 2"x1" |  | ||||||
| 88 |   | RP40-4824DFR/P-HC | 40 | Isolated | 18 - 75 | ± 24 | 2"x1" |  | ||||||
| 89 |   | RP40-4824SFR/N | 40 | Isolated | 18 - 75 | 21.6 to 28.8 | 2"x1" |  | ||||||
| 90 |   | RP40-4824SFR/N-HC | 40 | Isolated | 18 - 75 | 21.6 to 28.8 | 2"x1" |  | ||||||
| 91 |   | RP40-4824SFR/P | 40 | Isolated | 18 - 75 | 21.6 to 28.8 | 2"x1" |  | ||||||
| 92 |   | RP40-4824SFR/P-HC | 40 | Isolated | 18 - 75 | 21.6 to 28.8 | 2"x1" |  | ||||||
| 93 |   | RP40-483.3SFR/N | 40 | Isolated | 18 - 75 | 2.97 to 3.63 | 2"x1" |  | ||||||
| 94 |   | RP40-483.3SFR/N-HC | 40 | Isolated | 18 - 75 | 2.97 to 3.63 | 2"x1" |  | ||||||
| 95 |   | RP40-483.3SFR/P | 40 | Isolated | 18 - 75 | 2.97 to 3.63 | 2"x1" |  | ||||||
| 96 |   | RP40-483.3SFR/P-HC | 40 | Isolated | 18 - 75 | 2.97 to 3.63 | 2"x1" |  | 
| Attributes | RP40-FR | 
|---|---|
| AC/DC or DC/DC | DC/DC | 
| Power (W) | 40 | 
| Isolation | Isolated | 
| Mounting Type | THT | 
| Package Style | 2"x1" | 
| Width (mm) | 25.4 | 
| MIN Operating Temp (°C) | -40 | 
| MAX Operating Temp (°C) | 60 | 
| Protections | OLP, OTP, OVP, SCP | 
| Directives | REACH, RoHS 2+ (10/10) | 
| Warranty | 3 Years | 
| Regulation | Regulated | 
| Part Number | Power (W) | Vout 1 (V) | Vin (V) | Mounting Type | |||||
|---|---|---|---|---|---|---|---|---|---|
| 1 |   | RP40-11005SFR/N | 40 | 5 | 43 - 160 | THT |  | ||
| 2 |   | RP40-11005SFR/N-HC | 40 | 5 | 43 - 160 | THT |  | ||
| 3 |   | RP40-11005SFR/P | 40 | 5 | 43 - 160 | THT |  | ||
| 4 |   | RP40-11005SFR/P-HC | 40 | 5 | 43 - 160 | THT |  | ||
| 5 |   | RP40-11012DFR/N | 40 | 12 | 43 - 160 | THT |  | ||
| 6 |   | RP40-11012DFR/N-HC | 40 | 12 | 43 - 160 | THT |  | ||
| 7 |   | RP40-11012DFR/P | 40 | 12 | 43 - 160 | THT |  | ||
| 8 |   | RP40-11012DFR/P-HC | 40 | 12 | 43 - 160 | THT |  | ||
| 9 |   | RP40-11012SFR/N | 40 | 12 | 43 - 160 | THT |  | ||
| 10 |   | RP40-11012SFR/N-HC | 40 | 12 | 43 - 160 | THT |  | ||
| 11 |   | RP40-11012SFR/P | 40 | 12 | 43 - 160 | THT |  | ||
| 12 |   | RP40-11012SFR/P-HC | 40 | 12 | 43 - 160 | THT |  | ||
| 13 |   | RP40-11015DFR/N | 40 | 15 | 43 - 160 | THT |  | ||
| 14 |   | RP40-11015DFR/N-HC | 40 | 15 | 43 - 160 | THT |  | ||
| 15 |   | RP40-11015DFR/P | 40 | 15 | 43 - 160 | THT |  | ||
| 16 |   | RP40-11015DFR/P-HC | 40 | 15 | 43 - 160 | THT |  | ||
| 17 |   | RP40-11015SFR/N | 40 | 15 | 43 - 160 | THT |  | ||
| 18 |   | RP40-11015SFR/N-HC | 40 | 15 | 43 - 160 | THT |  | ||
| 19 |   | RP40-11015SFR/P | 40 | 15 | 43 - 160 | THT |  | ||
| 20 |   | RP40-11015SFR/P-HC | 40 | 15 | 43 - 160 | THT |  | ||
| 21 |   | RP40-11024DFR/N | 40 | 24 | 43 - 160 | THT |  | ||
| 22 |   | RP40-11024DFR/N-HC | 40 | 24 | 43 - 160 | THT |  | ||
| 23 |   | RP40-11024DFR/P | 40 | 24 | 43 - 160 | THT |  | ||
| 24 |   | RP40-11024DFR/P-HC | 40 | 24 | 43 - 160 | THT |  | ||
| 25 |   | RP40-11024SFR/N | 40 | 24 | 43 - 160 | THT |  | ||
| 26 |   | RP40-11024SFR/N-HC | 40 | 24 | 43 - 160 | THT |  | ||
| 27 |   | RP40-11024SFR/P | 40 | 24 | 43 - 160 | THT |  | ||
| 28 |   | RP40-11024SFR/P-HC | 40 | 24 | 43 - 160 | THT |  | ||
| 29 |   | RP40-1103.3SFR/N | 40 | 3.3 | 43 - 160 | THT |  | ||
| 30 |   | RP40-1103.3SFR/N-HC | 40 | 3.3 | 43 - 160 | THT |  | ||
| 31 |   | RP40-1103.3SFR/P | 40 | 3.3 | 43 - 160 | THT |  | ||
| 32 |   | RP40-1103.3SFR/P-HC | 40 | 3.3 | 43 - 160 | THT |  | ||
| 33 |   | RP40-2405SFR/N | 40 | 5 | 9 - 36 | THT |  | ||
| 34 |   | RP40-2405SFR/N-HC | 40 | 5 | 9 - 36 | THT |  | ||
| 35 |   | RP40-2405SFR/P | 40 | 5 | 9 - 36 | THT |  | ||
| 36 |   | RP40-2405SFR/P-HC | 40 | 5 | 9 - 36 | THT |  | ||
| 37 |   | RP40-2412DFR/N | 40 | 12 | 9 - 36 | THT |  | ||
| 38 |   | RP40-2412DFR/N-HC | 40 | 12 | 9 - 36 | THT |  | ||
| 39 |   | RP40-2412DFR/P | 40 | 12 | 9 - 36 | THT |  | ||
| 40 |   | RP40-2412DFR/P-HC | 40 | 12 | 9 - 36 | THT |  | ||
| 41 |   | RP40-2412SFR/N | 40 | 12 | 9 - 36 | THT |  | ||
| 42 |   | RP40-2412SFR/N-HC | 40 | 12 | 9 - 36 | THT |  | ||
| 43 |   | RP40-2412SFR/P | 40 | 12 | 9 - 36 | THT |  | ||
| 44 |   | RP40-2412SFR/P-HC | 40 | 12 | 9 - 36 | THT |  | ||
| 45 |   | RP40-2415DFR/N | 40 | 15 | 9 - 36 | THT |  | ||
| 46 |   | RP40-2415DFR/N-HC | 40 | 15 | 9 - 36 | THT |  | ||
| 47 |   | RP40-2415DFR/P | 40 | 15 | 9 - 36 | THT |  | ||
| 48 |   | RP40-2415DFR/P-HC | 40 | 15 | 9 - 36 | THT |  | ||
| 49 |   | RP40-2415SFR/N | 40 | 15 | 9 - 36 | THT |  | ||
| 50 |   | RP40-2415SFR/N-HC | 40 | 15 | 9 - 36 | THT |  | ||
| 51 |   | RP40-2415SFR/P | 40 | 15 | 9 - 36 | THT |  | ||
| 52 |   | RP40-2415SFR/P-HC | 40 | 15 | 9 - 36 | THT |  | ||
| 53 |   | RP40-2424DFR/N | 40 | 24 | 9 - 36 | THT |  | ||
| 54 |   | RP40-2424DFR/N-HC | 40 | 24 | 9 - 36 | THT |  | ||
| 55 |   | RP40-2424DFR/P | 40 | 24 | 9 - 36 | THT |  | ||
| 56 |   | RP40-2424DFR/P-HC | 40 | 24 | 9 - 36 | THT |  | ||
| 57 |   | RP40-2424SFR/N | 40 | 24 | 9 - 36 | THT |  | ||
| 58 |   | RP40-2424SFR/N-HC | 40 | 24 | 9 - 36 | THT |  | ||
| 59 |   | RP40-2424SFR/P | 40 | 24 | 9 - 36 | THT |  | ||
| 60 |   | RP40-2424SFR/P-HC | 40 | 24 | 9 - 36 | THT |  | ||
| 61 |   | RP40-243.3SFR/N | 40 | 3.3 | 9 - 36 | THT |  | ||
| 62 |   | RP40-243.3SFR/N-HC | 40 | 3.3 | 9 - 36 | THT |  | ||
| 63 |   | RP40-243.3SFR/P | 40 | 3.3 | 9 - 36 | THT |  | ||
| 64 |   | RP40-243.3SFR/P-HC | 40 | 3.3 | 9 - 36 | THT |  | ||
| 65 |   | RP40-4805SFR/N | 40 | 5 | 18 - 75 | THT |  | ||
| 66 |   | RP40-4805SFR/N-HC | 40 | 5 | 18 - 75 | THT |  | ||
| 67 |   | RP40-4805SFR/P | 40 | 5 | 18 - 75 | THT |  | ||
| 68 |   | RP40-4805SFR/P-HC | 40 | 5 | 18 - 75 | THT |  | ||
| 69 |   | RP40-4812DFR/N | 40 | 12 | 18 - 75 | THT |  | ||
| 70 |   | RP40-4812DFR/N-HC | 40 | 12 | 18 - 75 | THT |  | ||
| 71 |   | RP40-4812DFR/P | 40 | 12 | 18 - 75 | THT |  | ||
| 72 |   | RP40-4812DFR/P-HC | 40 | 12 | 18 - 75 | THT |  | ||
| 73 |   | RP40-4812SFR/N | 40 | 12 | 18 - 75 | THT |  | ||
| 74 |   | RP40-4812SFR/N-HC | 40 | 12 | 18 - 75 | THT |  | ||
| 75 |   | RP40-4812SFR/P | 40 | 12 | 18 - 75 | THT |  | ||
| 76 |   | RP40-4812SFR/P-HC | 40 | 12 | 18 - 75 | THT |  | ||
| 77 |   | RP40-4815DFR/N | 40 | 15 | 18 - 75 | THT |  | ||
| 78 |   | RP40-4815DFR/N-HC | 40 | 15 | 18 - 75 | THT |  | ||
| 79 |   | RP40-4815DFR/P | 40 | 15 | 18 - 75 | THT |  | ||
| 80 |   | RP40-4815DFR/P-HC | 40 | 15 | 18 - 75 | THT |  | ||
| 81 |   | RP40-4815SFR/N | 40 | 15 | 18 - 75 | THT |  | ||
| 82 |   | RP40-4815SFR/N-HC | 40 | 15 | 18 - 75 | THT |  | ||
| 83 |   | RP40-4815SFR/P | 40 | 15 | 18 - 75 | THT |  | ||
| 84 |   | RP40-4815SFR/P-HC | 40 | 15 | 18 - 75 | THT |  | ||
| 85 |   | RP40-4824DFR/N | 40 | 24 | 18 - 75 | THT |  | ||
| 86 |   | RP40-4824DFR/N-HC | 40 | 24 | 18 - 75 | THT |  | ||
| 87 |   | RP40-4824DFR/P | 40 | 24 | 18 - 75 | THT |  | ||
| 88 |   | RP40-4824DFR/P-HC | 40 | 24 | 18 - 75 | THT |  | ||
| 89 |   | RP40-4824SFR/N | 40 | 24 | 18 - 75 | THT |  | ||
| 90 |   | RP40-4824SFR/N-HC | 40 | 24 | 18 - 75 | THT |  | ||
| 91 |   | RP40-4824SFR/P | 40 | 24 | 18 - 75 | THT |  | ||
| 92 |   | RP40-4824SFR/P-HC | 40 | 24 | 18 - 75 | THT |  | ||
| 93 |   | RP40-483.3SFR/N | 40 | 3.3 | 18 - 75 | THT |  | ||
| 94 |   | RP40-483.3SFR/N-HC | 40 | 3.3 | 18 - 75 | THT |  | ||
| 95 |   | RP40-483.3SFR/P | 40 | 3.3 | 18 - 75 | THT |  | ||
| 96 |   | RP40-483.3SFR/P-HC | 40 | 3.3 | 18 - 75 | THT |  | 
| Title | Type | Date | 
|---|---|---|
| RP40-FR.pdf | Datasheet | 
| Title | Type | Date | 
|---|---|---|
| Power Supplies for Railway Data Communications | Blog Article | Aug 26, 2022 | 
| Rugged High-Power Converters Meet Stringent Railway Standards | Blog Article | Jul 15, 2022 | 
| The need for ultra-wide input range DC/DC converters | Blog Article | Jul 24, 2019 | 
| Railway Power Supplies | May 22, 2019 | |
| DC/DC Converters for On-board and Trackside Railway Applications | Mar 12, 2019 | 
| Title | Type | Date | 
|---|---|---|
| RPA: DC/DC Converters for Industry and Electromobility | Youtube Video | Mar 12, 2018 |