RACM30-K/277 AC/DC modules provide a leading thermally effective Power yield of 9.2 Watts per inch³ at 60°C still air for continuous loads of 30 Watts plus additional peak capability. These Modules operate in a temperature range of -40° to 90°C in compliance with safety standards of medical MOPP, household-, industrial, and measurement markets. Safety reports rate the series as LPS limited power source and OVCIII for an operating altitude of up to 5000m. A comfortable margin to EMI Class B limits, even with outputs connected to the ground, ease system implementation for quick time-to-market without additional external circuitry such as fuses or filters. For designers, maximum flexibility for these encapsulated, “THT”-through hole technology solder-mountable modules is pin-to-pin compatible with the well-established series RAC20-K. Further mechanical derivates are potted modules with wires or a panel mount option with spring-clamp connectors which is convertible to DIN-Rail mounting via available RECOM Clip accessory.
Attributes | RACM30-15DK/277/OF |
---|---|
AC/DC or DC/DC | AC/DC |
Power (W) | 30.0 |
Isolation | Isolated |
Vin (V) | 85.0 - 305.0 |
Main Vout (V) | ± 15 |
Nr. of Outputs | Dual |
Iout 1 (mA) | 1000.0 |
Iout 2 (mA) | -1000.0 |
Isolation (kV) | 4.0 |
Mounting Type | Connector |
Package Style | Open Frame 1.5"x3" |
Length (mm) | 76.2 |
Width (mm) | 38.1 |
Height (mm) | 25.0 |
Certifications | CB, CE, EN 55032, EN 60335-1, EN 60601-1, EN 60601-1-2, EN 62368-1, UL 60601-1 |
MIN Operating Temp (°C) | -40.0 |
MAX Operating Temp (°C) | 50.0 |
Protections | OCP, OVP, SCP |
Directives | REACH, RoHS 2+ (10/10) |
Packaging Type | Tray |
Warranty | 3 Years |
Regulation | Regulated |
표제 | Type | 날짜 |
---|---|---|
RACM30-K_277.pdf | Datasheet | |
RACM30-K_277_OF_installation_guide.pdf | Installation | 2023. 9. 6 |
RACM30-DK_277_OF.STEP | 2D/3D | 2022. 6. 2 |
표제 | Type | 날짜 |
---|---|---|
이제 30W의 RACMxx-K/277 시리즈 사용이 가능합니다. | Official Press Release | 2023. 2. 22 |