The REM60-W series of medical grade regulated DC/DC converters features reinforced 5kVAC/1minute isolation with low 4.5µA leakage (B, BF and CF compatible) and are 60601-1 3rd Ed. certified for 250VAC continuous working voltage isolation. The industry standard 2.3”x1.5” package offers tightly regulated single and dual outputs which can operate down to zero load. The outputs are also short circuit and overload protected. The converters are certified to IEC/EN and ANSI/AAMI standards and carry the UL mark.
Part Number | Power (W) | Isolation | Vin (V) | Main Vout (V) | Package Style | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1 |
REM60-2405SW
Fokus
| 60.0 | Isolated | 9.0 - 36.0 | 5 | 2.3"x1.5" |
| |||||||
2 |
REM60-2412DW
Fokus
| 60.0 | Isolated | 9.0 - 36.0 | ± 12 | 2.3"x1.5" |
| |||||||
3 |
REM60-2412SW
Fokus
| 60.0 | Isolated | 9.0 - 36.0 | 12 | 2.3"x1.5" |
| |||||||
4 |
REM60-2415DW
Fokus
| 60.0 | Isolated | 9.0 - 36.0 | ± 15 | 2.3"x1.5" |
| |||||||
5 |
REM60-2415SW
Fokus
| 60.0 | Isolated | 9.0 - 36.0 | 15 | 2.3"x1.5" |
| |||||||
6 |
REM60-2424SW
Fokus
| 60.0 | Isolated | 9.0 - 36.0 | 24 | 2.3"x1.5" |
| |||||||
7 |
REM60-245.1SW
Fokus
| 60.0 | Isolated | 9.0 - 36.0 | 5.1 | 2.3"x1.5" |
| |||||||
8 |
REM60-4805SW
Fokus
| 60.0 | Isolated | 18.0 - 75.0 | 5 | 2.3"x1.5" |
| |||||||
9 |
REM60-4812DW
Fokus
| 60.0 | Isolated | 18.0 - 75.0 | ± 12 | 2.3"x1.5" |
| |||||||
10 |
REM60-4812SW
Fokus
| 60.0 | Isolated | 18.0 - 75.0 | 12 | 2.3"x1.5" |
| |||||||
11 |
REM60-4815DW
Fokus
| 60.0 | Isolated | 18.0 - 75.0 | ± 15 | 2.3"x1.5" |
| |||||||
12 |
REM60-4815SW
Fokus
| 60.0 | Isolated | 18.0 - 75.0 | 15 | 2.3"x1.5" |
| |||||||
13 |
REM60-4824SW
Fokus
| 60.0 | Isolated | 18.0 - 75.0 | 24 | 2.3"x1.5" |
| |||||||
14 |
REM60-485.1SW
Fokus
| 60.0 | Isolated | 18.0 - 75.0 | 5.1 | 2.3"x1.5" |
|
Attributes | REM60-W |
---|---|
AC/DC or DC/DC | DC/DC |
Power (W) | 60.0 |
Isolation | Isolated |
Isolation (kV) | 5.0 |
Mounting Type | THT |
Package Style | 2.3"x1.5" |
Length (mm) | 57.9 |
Width (mm) | 36.8 |
Height (mm) | 12.7 |
Certifications | EN 55032, EN 60601-1, EN 60601-1-2, EN 62368-1, UL 60601-1, UL 62368-1 |
MIN Operating Temp (°C) | -40.0 |
MAX Operating Temp (°C) | 40.0 |
Protections | OLP, OTP, OVP, SCP |
Control Pin Function | Positive |
Directives | REACH, RoHS 2+ (10/10) |
Packaging Type | Tray |
Warranty | 3 Years |
Regulation | Regulated |
Part Number | Power (W) | Vout 1 (V) | Vin (V) | Mounting Type | |||||
---|---|---|---|---|---|---|---|---|---|
1 |
REM60-2405SW
Fokus
| 60.0 | 5.0 | 9.0 - 36.0 | THT |
| |||
2 |
REM60-2412DW
Fokus
| 60.0 | 12.0 | 9.0 - 36.0 | THT |
| |||
3 |
REM60-2412SW
Fokus
| 60.0 | 12.0 | 9.0 - 36.0 | THT |
| |||
4 |
REM60-2415DW
Fokus
| 60.0 | 15.0 | 9.0 - 36.0 | THT |
| |||
5 |
REM60-2415SW
Fokus
| 60.0 | 15.0 | 9.0 - 36.0 | THT |
| |||
6 |
REM60-2424SW
Fokus
| 60.0 | 24.0 | 9.0 - 36.0 | THT |
| |||
7 |
REM60-245.1SW
Fokus
| 60.0 | 5.1 | 9.0 - 36.0 | THT |
| |||
8 |
REM60-4805SW
Fokus
| 60.0 | 5.0 | 18.0 - 75.0 | THT |
| |||
9 |
REM60-4812DW
Fokus
| 60.0 | 12.0 | 18.0 - 75.0 | THT |
| |||
10 |
REM60-4812SW
Fokus
| 60.0 | 12.0 | 18.0 - 75.0 | THT |
| |||
11 |
REM60-4815DW
Fokus
| 60.0 | 15.0 | 18.0 - 75.0 | THT |
| |||
12 |
REM60-4815SW
Fokus
| 60.0 | 15.0 | 18.0 - 75.0 | THT |
| |||
13 |
REM60-4824SW
Fokus
| 60.0 | 24.0 | 18.0 - 75.0 | THT |
| |||
14 |
REM60-485.1SW
Fokus
| 60.0 | 5.1 | 18.0 - 75.0 | THT |
|
Titel | Typ | Datum |
---|---|---|
REM60-W.pdf | Datasheet |
Titel | Typ | Datum |
---|---|---|
REM60-W liefert 60W mit medizinischer Zertifizierung | Official Press Release | 05.07.2023 |