The RAC04-xxS_DC/277 series are fully certified single and dual regulated AC/DC converters in an encapsulated PCB-mount package style with 3.75kVAC isolation and very low stand-by power consumption. The modules are suitable for worldwide use due to their wide input voltage range from 80VAC to 305VAC. Possible uses include home automation, standby applications and industrial controls.
| Part Number | Power (W) | Isolation | Vin (V) | Main Vout (V) | Iout 1 (mA) | Package Style | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 |   | RAC04-0512DC/277 
NRND
 | 4 | Isolated | 80 - 305 | 5 / 12 | 720 | Standard |  | ||||||
| 2 |   | RAC04-0512DC/277-E 
NRND
 | 4 | Isolated | 80 - 305 | 5 / 12 | 720 | Standard |  | ||||||
| 3 |   | RAC04-05DC/277 
NRND
 | 4 | Isolated | 80 - 305 | ± 5 | 400 | Standard |  | ||||||
| 4 |   | RAC04-05DC/277-E 
NRND
 | 4 | Isolated | 80 - 305 | ± 5 | 400 | Standard |  | ||||||
| 5 |   | RAC04-05SC/277 
NRND
 | 4 | Isolated | 80 - 305 | 5 | 800 | Standard |  | ||||||
| 6 |   | RAC04-05SC/277-E 
NRND
 | 4 | Isolated | 80 - 305 | 5 | 800 | Standard |  | ||||||
| 7 |   | RAC04-12DC/277 
NRND
 | 4 | Isolated | 80 - 305 | ± 12 | 166 | Standard |  | ||||||
| 8 |   | RAC04-12DC/277-E 
NRND
 | 4 | Isolated | 80 - 305 | ± 12 | 166 | Standard |  | ||||||
| 9 |   | RAC04-12SC/277 
NRND
 | 4 | Isolated | 80 - 305 | 12 | 333 | Standard |  | ||||||
| 10 |   | RAC04-12SC/277-E 
NRND
 | 4 | Isolated | 80 - 305 | 12 | 333 | Standard |  | ||||||
| 11 |   | RAC04-15SC/277 
NRND
 | 4 | Isolated | 80 - 305 | 15 | 267 | Standard |  | ||||||
| 12 |   | RAC04-15SC/277-E 
NRND
 | 4 | Isolated | 80 - 305 | 15 | 267 | Standard |  | ||||||
| 13 |   | RAC04-24SC/277 
NRND
 | 4 | Isolated | 80 - 305 | 24 | 167 | Standard |  | ||||||
| 14 |   | RAC04-24SC/277-E 
NRND
 | 4 | Isolated | 80 - 305 | 24 | 167 | Standard |  | ||||||
| 15 |   | RAC04-3.3SC/277 
NRND
 | 4 | Isolated | 80 - 305 | 3.3 | 1200 | Standard |  | ||||||
| 16 |   | RAC04-3.3SC/277-E 
NRND
 | 4 | Isolated | 80 - 305 | 3.3 | 1200 | Standard |  | 
| Attributes | RAC04-C/277 | 
|---|---|
| AC/DC or DC/DC | AC/DC | 
| Power (W) | 4 | 
| Isolation | Isolated | 
| Vin (V) | 80 - 305 | 
| Isolation (kV) | 3.75 | 
| Mounting Type | THT | 
| Package Style | Standard | 
| Length (mm) | 36.7 | 
| Width (mm) | 27.2 | 
| Height (mm) | 17.1 | 
| Certifications | CB, CE, EN 55024, EN 55032, EN 60950-1, EN 62368-1, IEC 60950-1, UL 60950-1 | 
| MAX Operating Temp (°C) | 65 | 
| Protections | SCP | 
| Directives | REACH, RoHS 2+ (10/10) | 
| Packaging Type | Tube | 
| Warranty | 3 Years | 
| Regulation | Regulated | 
| Part Number | Power (W) | Vout 1 (V) | Vin (V) | Mounting Type | |||||
|---|---|---|---|---|---|---|---|---|---|
| 1 |   | RAC04-0512DC/277 
NRND
 | 4 | 5 | 80 - 305 | THT |  | ||
| 2 |   | RAC04-0512DC/277-E 
NRND
 | 4 | 5 | 80 - 305 | THT |  | ||
| 3 |   | RAC04-05DC/277 
NRND
 | 4 | 5 | 80 - 305 | THT |  | ||
| 4 |   | RAC04-05DC/277-E 
NRND
 | 4 | 5 | 80 - 305 | THT |  | ||
| 5 |   | RAC04-05SC/277 
NRND
 | 4 | 5 | 80 - 305 | THT |  | ||
| 6 |   | RAC04-05SC/277-E 
NRND
 | 4 | 5 | 80 - 305 | THT |  | ||
| 7 |   | RAC04-12DC/277 
NRND
 | 4 | 12 | 80 - 305 | THT |  | ||
| 8 |   | RAC04-12DC/277-E 
NRND
 | 4 | 12 | 80 - 305 | THT |  | ||
| 9 |   | RAC04-12SC/277 
NRND
 | 4 | 12 | 80 - 305 | THT |  | ||
| 10 |   | RAC04-12SC/277-E 
NRND
 | 4 | 12 | 80 - 305 | THT |  | ||
| 11 |   | RAC04-15SC/277 
NRND
 | 4 | 15 | 80 - 305 | THT |  | ||
| 12 |   | RAC04-15SC/277-E 
NRND
 | 4 | 15 | 80 - 305 | THT |  | ||
| 13 |   | RAC04-24SC/277 
NRND
 | 4 | 24 | 80 - 305 | THT |  | ||
| 14 |   | RAC04-24SC/277-E 
NRND
 | 4 | 24 | 80 - 305 | THT |  | ||
| 15 |   | RAC04-3.3SC/277 
NRND
 | 4 | 3.3 | 80 - 305 | THT |  | ||
| 16 |   | RAC04-3.3SC/277-E 
NRND
 | 4 | 3.3 | 80 - 305 | THT |  | 
| Titel | Typ | Datum | 
|---|---|---|