The REM30 series of medical grade regulated DC/DC converters features reinforced 5kVAC/1 minute isolation with low 2µA leakage (B, BF and CF compatible) and are 60601-1 3rd Ed. certified for 250VAC continuous working voltage isolation. The industry standard 2"x1" package offers tightly regulated single and dual outputs, with low output ripple and zero-load operation. The outputs are also short circuit and overload protected. The converters are certified to CB, IEC/EN and ANSI/AAMI standards and carry the UL mark.
| Part Number | Power (W) | Isolation | Vin (V) | Main Vout (V) | Package Style | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 |   | REM30-2405DW | 30 | Isolated | 9 - 36 | ± 5 | 2"x1" |  | ||||||
| 2 |   | REM30-2405DW/P | 30 | Isolated | 9 - 36 | ± 5 | 2"x1" |  | ||||||
| 3 |   | REM30-2405SW | 30 | Isolated | 9 - 36 | 4.5 to 5.5 | 2"x1" |  | ||||||
| 4 |   | REM30-2405SW/P | 30 | Isolated | 9 - 36 | 4.5 to 5.5 | 2"x1" |  | ||||||
| 5 |   | REM30-2412DW | 30 | Isolated | 9 - 36 | ± 12 | 2"x1" |  | ||||||
| 6 |   | REM30-2412DW/P | 30 | Isolated | 9 - 36 | ± 12 | 2"x1" |  | ||||||
| 7 |   | REM30-2412SW | 30 | Isolated | 9 - 36 | 10.8 to 13.2 | 2"x1" |  | ||||||
| 8 |   | REM30-2412SW/P | 30 | Isolated | 9 - 36 | 10.8 to 13.2 | 2"x1" |  | ||||||
| 9 |   | REM30-2415DW | 30 | Isolated | 9 - 36 | ± 15 | 2"x1" |  | ||||||
| 10 |   | REM30-2415DW/P | 30 | Isolated | 9 - 36 | ± 15 | 2"x1" |  | ||||||
| 11 |   | REM30-2415SW | 30 | Isolated | 9 - 36 | 13.5 to 18 | 2"x1" |  | ||||||
| 12 |   | REM30-2415SW/P | 30 | Isolated | 9 - 36 | 13.5 to 18 | 2"x1" |  | ||||||
| 13 |   | REM30-2424SW | 30 | Isolated | 9 - 36 | 21.6 to 28.8 | 2"x1" |  | ||||||
| 14 |   | REM30-2424SW/P | 30 | Isolated | 9 - 36 | 21.6 to 28.8 | 2"x1" |  | ||||||
| 15 |   | REM30-4805DW | 30 | Isolated | 18 - 75 | ± 5 | 2"x1" |  | ||||||
| 16 |   | REM30-4805DW/P | 30 | Isolated | 18 - 75 | ± 5 | 2"x1" |  | ||||||
| 17 |   | REM30-4805SW | 30 | Isolated | 18 - 75 | 4.5 to 5.5 | 2"x1" |  | ||||||
| 18 |   | REM30-4805SW/P | 30 | Isolated | 18 - 75 | 4.5 to 5.5 | 2"x1" |  | ||||||
| 19 |   | REM30-4812DW | 30 | Isolated | 18 - 75 | ± 12 | 2"x1" |  | ||||||
| 20 |   | REM30-4812DW/P | 30 | Isolated | 18 - 75 | ± 12 | 2"x1" |  | ||||||
| 21 |   | REM30-4812SW | 30 | Isolated | 18 - 75 | 10.8 to 13.2 | 2"x1" |  | ||||||
| 22 |   | REM30-4812SW/P | 30 | Isolated | 18 - 75 | 10.8 to 13.2 | 2"x1" |  | ||||||
| 23 |   | REM30-4815DW | 30 | Isolated | 18 - 75 | ± 15 | 2"x1" |  | ||||||
| 24 |   | REM30-4815DW/P | 30 | Isolated | 18 - 75 | ± 15 | 2"x1" |  | ||||||
| 25 |   | REM30-4815SW | 30 | Isolated | 18 - 75 | 13.5 to 18 | 2"x1" |  | ||||||
| 26 |   | REM30-4815SW/P | 30 | Isolated | 18 - 75 | 13.5 to 18 | 2"x1" |  | ||||||
| 27 |   | REM30-4824SW | 30 | Isolated | 18 - 75 | 21.6 to 28.8 | 2"x1" |  | ||||||
| 28 |   | REM30-4824SW/P | 30 | Isolated | 18 - 75 | 21.6 to 28.8 | 2"x1" |  | 
| Attributes | REM30-W | 
|---|---|
| AC/DC or DC/DC | DC/DC | 
| Power (W) | 30 | 
| Isolation | Isolated | 
| Isolation (kV) | 5 | 
| Mounting Type | THT | 
| Package Style | 2"x1" | 
| Length (mm) | 50.8 | 
| Width (mm) | 25.4 | 
| Height (mm) | 10.2 | 
| Certifications | CB, EN 60601-1-2, UL 60601-1, UL 60950-1, UL 62368-1 | 
| MIN Operating Temp (°C) | -40 | 
| MAX Operating Temp (°C) | 105 | 
| Protections | OLP, OTP, OVP, SCP | 
| Directives | REACH, RoHS 2+ (10/10) | 
| Packaging Type | Tube | 
| Warranty | 5 Years | 
| Regulation | Regulated | 
| Part Number | Power (W) | Vout 1 (V) | Vin (V) | Mounting Type | |||||
|---|---|---|---|---|---|---|---|---|---|
| 1 |   | REM30-2405DW | 30 | 5 | 9 - 36 | THT |  | ||
| 2 |   | REM30-2405DW/P | 30 | 5 | 9 - 36 | THT |  | ||
| 3 |   | REM30-2405SW | 30 | 5 | 9 - 36 | THT |  | ||
| 4 |   | REM30-2405SW/P | 30 | 5 | 9 - 36 | THT |  | ||
| 5 |   | REM30-2412DW | 30 | 12 | 9 - 36 | THT |  | ||
| 6 |   | REM30-2412DW/P | 30 | 12 | 9 - 36 | THT |  | ||
| 7 |   | REM30-2412SW | 30 | 12 | 9 - 36 | THT |  | ||
| 8 |   | REM30-2412SW/P | 30 | 12 | 9 - 36 | THT |  | ||
| 9 |   | REM30-2415DW | 30 | 15 | 9 - 36 | THT |  | ||
| 10 |   | REM30-2415DW/P | 30 | 15 | 9 - 36 | THT |  | ||
| 11 |   | REM30-2415SW | 30 | 15 | 9 - 36 | THT |  | ||
| 12 |   | REM30-2415SW/P | 30 | 15 | 9 - 36 | THT |  | ||
| 13 |   | REM30-2424SW | 30 | 24 | 9 - 36 | THT |  | ||
| 14 |   | REM30-2424SW/P | 30 | 24 | 9 - 36 | THT |  | ||
| 15 |   | REM30-4805DW | 30 | 5 | 18 - 75 | THT |  | ||
| 16 |   | REM30-4805DW/P | 30 | 5 | 18 - 75 | THT |  | ||
| 17 |   | REM30-4805SW | 30 | 5 | 18 - 75 | THT |  | ||
| 18 |   | REM30-4805SW/P | 30 | 5 | 18 - 75 | THT |  | ||
| 19 |   | REM30-4812DW | 30 | 12 | 18 - 75 | THT |  | ||
| 20 |   | REM30-4812DW/P | 30 | 12 | 18 - 75 | THT |  | ||
| 21 |   | REM30-4812SW | 30 | 12 | 18 - 75 | THT |  | ||
| 22 |   | REM30-4812SW/P | 30 | 12 | 18 - 75 | THT |  | ||
| 23 |   | REM30-4815DW | 30 | 15 | 18 - 75 | THT |  | ||
| 24 |   | REM30-4815DW/P | 30 | 15 | 18 - 75 | THT |  | ||
| 25 |   | REM30-4815SW | 30 | 15 | 18 - 75 | THT |  | ||
| 26 |   | REM30-4815SW/P | 30 | 15 | 18 - 75 | THT |  | ||
| 27 |   | REM30-4824SW | 30 | 24 | 18 - 75 | THT |  | ||
| 28 |   | REM30-4824SW/P | 30 | 24 | 18 - 75 | THT |  | 
| Title | Type | Date | 
|---|---|---|
| REM30-W.pdf | Datasheet | 
| Title | Type | Date | 
|---|---|---|
| Handling High Voltages in E-Mobility / EV Traction Battery Tester | Case Study | Dec 22, 2022 | 
| Medical Grade DC/DC Converters - REM Series | Podcast | Feb 17, 2020 | 
| Medical Power Supplies | Aug 22, 2019 | |
| Powering patient-connected medical devices with DC-DC converters | Blog Article | Jun 12, 2019 | 
| Board-mount DC-DC converters in medical applications | Blog Article | May 15, 2019 | 
| Medical Power Supplies | Apr 15, 2019 | |
| 15, 20 and 30W Medical DC/DC Converters provide 2MOPP | Official Press Release | Oct 25, 2018 | 
| Title | Type | Date | 
|---|---|---|
| Medical-Grade Low-Power Converters | Video | Jun 4, 2020 | 
| RECOM Medical: High-grade DC/DC converters and compact AC/DC power supplies | Youtube Video | Nov 20, 2018 |